(5)
Disconnect 1 connector to take off the lifting
tray lower limit detection sensor.
[G-3]
Original length detection sensor (S63)
(1)
Take off the lower guide
(
P.16-94 "[G-2] Lifting tray lower limit
detection sensor (S62)").
(2)
Disconnect 1 connector and remove 1 screw.
Then take off the original length detection
sensor with its bracket.
(3)
Remove 1 screw to take off the original
length detection sensor from its bracket.
[G-4]
Jam access cover opening/closing switch (SW10)
(1)
Take off the ADF rear cover
(
P.16-86 "[B-2] ADF rear cover").
(2)
Remove 1 screw to take off the jam access
cover opening/closing switch.
March 2005 © TOSHIBA TEC
Lifting tray lower limit detection sensor
Screw
Jam access cover opening/closing switch
e-STUDIO520/600/720/850 REVERSING AUTOMATIC DOCUMENT FEEDER (RADF)
16 - 95
Fig.16-134
Original length detection sensor
Fig.16-135
Screw
Fig.16-136
16