Toshiba e-STUDIO520 Service Manual page 314

Multifunctional digital systems
Hide thumbs Also See for e-STUDIO520:
Table of Contents

Advertisement

(5)
Remove the spring to take off the upper sep-
aration fingers.
[F]
Lower separation finger unit / Lower separation finger
(1)
Take off the fuser unit
(
P.14-18 "[B] Fuser unit").
(2)
Remove 2 screws and open the lower sepa-
ration finger unit.
(3)
Remove the spring to take off the lower sep-
aration fingers.
[G] Fuser roller front/center/rear thermistor (THM1 / THM 2 / THM 3), Fuser roller center/side thermo-
stat (THMO1 / THMO2)
(1)
Take off the fuser unit
(
P.14-18 "[B] Fuser unit").
(2)
Take off the cleaning web unit
(
P.14-19 "[C] Cleaning web unit / Clean-
ing web").
(3)
Loosen 2 pressure screws completely.
e-STUDIO520/600/720/850 FUSER UNIT
Upper separation finger
Lower separation finger
14 - 24
Spring
Fig.14-27
Spring
Fig.14-28
Pressure screw
Fig.14-29
March 2005 © TOSHIBA TEC