Print Head Temperature Thresholds

1300
HTEMP:H:STOP
1301
HTEMP:H:JUDG
1302
HTEMP:H:RCVR
1303
HTEMP:L:RCVR
1304
HTEMP:L:JUDG
1305
HTEMP:L:STOP
Use this SP to set the threshold for the operating temperature range of the print
head.
[0 to 65535/0/1/0.1

Ambient Temperature Thresholds

1306
ETEMP:H:STOP
1307
ETEMP:H:JUDG
1308
ETEMP:H:RCVR
1309
ETEMP:L:RCVR
1310
ETEMP:L:JUDG
1311
ETEMP:L:RCVR
Use this SP to set the threshold for the operating humidity range of the print head.
[0 to 65535/0/1/0.1
SM
CÓPIA NÃO CONTROLADA
Trigger Shutdown: Standby, Printing
Trigger Shutdown: Power On
Recovery After High Temp Shutdown
Recovery After Low Temp Shutdown
Trigger Shutdown: Power On
Trigger Shutdown: Standby, Printing
o
C
High Temperature to Trigger Shutdown: Standby, Printing
High Temperature to Trigger Shutdown: Power On
Recovery After High Temp Shutdown
Recovery After Low Temp Shutdown
Low Temperature to Trigger Shutdown: Power On
Low Temperature to Trigger Shutdown: Standby, Printing
o
C