Charge Width Setting Mj4: Duplex (Dfu); Calibrate Humidity/Temperature For Duplex - Ricoh J012 Service Manual

Table of Contents

Advertisement

SP Mode Service Tables

Charge Width Setting Mj4: Duplex (DFU)

1156
CHG:W2:EDGE:13
1158
CHG:W2:EDGE:14
1160
CHG:W2:EDGE:15
1162
CHG:W2:EDGE:16
1157
CHG:W2:MIDL:13
1159
CHG:W2: MIDL:14
1161
CHG:W2: MIDL:15
1163
CHG:W2: MIDL:16

Calibrate Humidity/Temperature for Duplex

1164
CHG:HUMI:B
Use this SP to calibrate the temperature/humidity sensor for humidity readings
during duplex printing. Do this SP to update the charge pitch table for duplex
printing. This SP setting is linked to the humidity steps in the charge pitch tables
(SP1200 to SP1231).
[-128 to +127/0/1/0.1%]
1165
CHG:TEMP:B
Use this SP to calibrate the temperature readings for duplex printing. Do this SP
to update the charge pitch table for duplex printing. This SP setting is linked to the
temperature steps in the charge pitch tables (SP1200 to SP1231).
[-128 to +127/0/1/0.1%]
J012/J013/J014
CÓPIA NÃO CONTROLADA
LE/TE: Mj4: ID1
LE/TE: Mj4: ID2
LE/TE: Mj4: ID3
LE/TE: Mj4: ID4
MIDL: Mj4: ID1
MIDL: Mj4: ID2
MIDL: Mj4: ID3
MIDL: Mj4: ID4
Calibrate Humidity Setting for Duplex