Maintenance Unit
4.
Remove screws [1] and [2] ( x2).
5.
Disconnect the unit [3] (
6.
Pull the unit [4] out of the unit as shown.
Handle the maintenance unit carefully. The bottom of the unit may be covered
with ink. Do not touch the bottom of the unit.
7.
Remove screws [5] and [6], to disconnect the maintenance unit motor from the
maintenance unit ( x2)
8.
Set the maintenance unit [7] on a cloth or sheet of paper.
J012/J013/J014
CÓPIA NÃO CONTROLADA
x1).
3-32
CÓPIA NÃO CONTROLADA
SM