Cabling The Hp Storeall 8800 Storage System - HP StoreAll Series Installation Manual

Table of Contents

Advertisement

Cabling the HP StoreAll 8800 Storage system

Note the following guidelines when connecting the 8800 to MDL SAS or ENT SAS capacity blocks:
Controller 1 contains ports 1 and 2 in slot 1. Together, these ports form a controller pair.
Controller 2 contains ports 1 and 2 in slot 4. Together these ports form a controller pair.
The initial connection must be made from controller 1 (port 1 in slot 1) on the StoreAll node.
Port 1 of each controller (in slot 1 and slot 4) connects to I/O module A on the capacity block.
Port 2 of each controller (in slot 1 and slot 4) connects to I/O module B on the capacity block.
Port 1 and port 2 of the same controller (either controller 1 or controller 2) should connect to
different drawers in the MDS SAS capacity block.
Each controller pair can support a single MDL SAS capacity block or up to 4 ENT SAS capacity
blocks.
When connecting a SAS chain of up to 4 ENT SAS capacity blocks, port 1 in each controller
pair connects to either I/O module A in the top capacity block or I/O module A in the bottom
capacity block.
When connecting the capacity blocks together, connect I/O module A on each capacity block
in a "top to bottom" order; connect I/O module B in each capacity block in a "bottom to top"
order.
Figure 25 HP StoreAll 8800 Storage system cabling with one ENT SAS capacity block
1. SAS ENT capacity block
2. HP StoreAll node 1, port 2 in slot 1 to SAS ENT capacity block (port 1 of I/O module B)
3. HP StoreAll node 1
4. HP StoreAll node 2
5. HP StoreAll node 2, port 2 in slot 1 to SAS ENT capacity block (port 2 of I/O module B)
6. HP StoreAll node 2, port 1 in slot 1 to SAS ENT capacity block (port 2 of I/O module A)
7. HP StoreAll node 1, port 1 in slot 1 to SAS ENT capacity block (port 1 of I/O module A)
Cabling HP StoreAll Storage system components
33

Hide quick links:

Advertisement

Table of Contents
loading