Figure 29 HP StoreAll 8800 Storage system cabling with two MDL SAS capacity blocks
1. HP StoreAll node 2
2. HP StoreAll node 2
3. Node 1, port 2 in slot 4 to MDL SAS capacity block 2,
drawer 2 (I/O module B, port 2)
4. HP SAS MDL capacity block 2 (top)
5. HP MDL SAS capacity block 1 (bottom)
6. Node 2, port 1 in slot 1 to MDL SAS capacity block 1,
drawer 2 (I/O module A, port 2)
7. Node 1, port 2 in slot 1 to MDL SAS capacity block 1,
drawer 2 (I/O module B, port 2)
8. Node 2, port 1 in slot 4 to MDL SAS capacity block 2,
drawer 2 (I/O module A, port 2)
9. Node 2, port 2 in slot 4 to MDL SAS capacity block 2,
drawer 1 (I/O module B, port 1)
10. Node 2, port 2 in slot 1 to MDL SAS capacity block
1, drawer 1 (I/O module B, port 1)
1 1. Node 1, port 1 in slot 1 to MDL SAS capacity block
1, drawer 1 (I/O module A, port 1)
12. Port 1 of I/O module A in drawer 2 to port 2 of I/O
module A in drawer 1 of MDL SAS capacity block 2
13. Node 1, port 1 in slot 4 to MDL SAS capacity block
2, drawer 1 (I/O module A, port 1)
14. Port 1 of I/O module B in drawer 2 to port 2 of I/O
module B in drawer 1 of MDL SAS capacity block 2
15. Port 1 in I/O module A of drawer 2 to port 2 of I/O
module A in drawer 1 of MDL SAS capacity block 1
16. Port 1 in I/O module B of drawer 2 to port 2 of I/O
module B in drawer 1 of MDL SAS capacity block 1
Cabling HP StoreAll Storage system components