Aastra 9000i Series Administrator's Manual page 261

Ip sip phones
Hide thumbs Also See for 9000i Series:
Table of Contents

Advertisement

Aastra Web UI
Step
Action
6
In the Codec Preference List, select a codec (with its payload type) you want the phones to use.
Valid values are:
All
Basic (G.711 u-law, G.711 a-law, G.729)
G722
G711u/8K
G711u/16K
G711a/8K
G711a/16K
G729
G726-16
G726-24
G726-32
G726-40
BV16 (8K)
BV32 (16K)
L16 (8K)
L16 (16K)
Notes:
1.
Setting Codec 1 to "All" ignores the packetization interval (ptime). The packetization interval
setting defaults to 30, which is the default for all codecs.
2.
Setting Codec 1 to "All" automatically sets all other codec preference fields 2 through 10 to
"None".
3.
Setting Codec 1 to "Basic" and all other codec preferences in 2 through 10 to "None", forces
the phone to use only the basic codecs as in previous releases (G.711 u-law, G.711 a-law, and
G.729). If you select an additional codec to use in the codec preferences 2 through 10 fields, those
codecs are added to the list of Basic codecs for the phone to use.
7
(Optional) In Codec 2 through Codec 10, select a preference of codecs (with its payload type) to use
on the phone. Valid values are:
None
G722
G711u/8K
G711u/16K
G711a/8K
G711a/16K
G729
G726-16
G726-24
G726-32
G726-40
BV16 (8K)
BV32 (16K)
L16 (8K)
L16 (16K)
Note: You can select up to 9 codecs in addition to the codec you selected in step 6.
8
In the "Packetization Interval" field, select the time, in milliseconds. Valid values are 5 to 90, in
increments of 5 milliseconds.
4-98
41-001343-01 Rev 02, Release 3.2.2

Advertisement

Table of Contents
loading

This manual is also suitable for:

6700i series9000i6700i

Table of Contents