Config Ipxsap Vlan Update-Interval - Extreme Networks ExtremeWare Command Reference Manual

Version 7.0.0
Hide thumbs Also See for ExtremeWare:
Table of Contents

Advertisement

IPX Commands

config ipxsap vlan update-interval

config ipxsap vlan [<vlan name> | all] update-interval <time>
{hold-multiplier <number>}
Description
Configures the update interval and hold multiplier for IPX/SAP updates.
Syntax Description
vlan name
all
update-interval <time>
hold-multiplier <number>
Default
The default update interval is 60 seconds. The default multiplier is 3.
Usage Guidelines
This setting affects both the periodic update interval of SAP and the aging interval of learned routes.
The default update interval is 60 seconds. The aging period is calculated using the formula
(update-interval * multiplier). The default multiplier is 3. Triggered update is always enabled; therefore,
new information is processed and propagated immediately.
Example
The following command configures an update interval of
IPX/SAP updates for VLAN
config ipxsap vlan accounting update-interval 30 hold-multiplier 2
History
This command was introduced in ExtremeWare 4.0.
Platform Availability
This command is available on the all "i" series systems.
1202
Specifies a VLAN name.
Specifies all VLANs.
Specifies the update interval time.
Specifies the hold multiplier for IPX/RIP updates.
:
accounting
seconds and a hold multiplier of 2 for the
30
ExtremeWare Software 7.0.0 Command Reference Guide