Data Conversion
Correction of touch switch position and size
S Difference
New models:
Conventional models:
Switches:
S Conversion result, error message and corrective action
Status before
Conversion
With a conventional
With a new model,
model, an alarm list/
the associated
history is registered
touch switches are
for a screen and
deleted and the
touch switches are
control touch
associated with it.
switches (in the ini-
tial state) are auto-
matically created.
When converted to
the NT21,
NT31/631-V2 or lat-
er models
(NT20/30/620-com-
patible mode on)
associated touch
switches will be
converted to control
touch switches, oth-
er properties re-
maining the same.
With a conventional
With a new model,
model, an alarm list/
control touch
history is registered
switches (in the ini-
for a screen (with-
tial state) are auto-
out control touch
matically created.
switches).
With a new model,
With a conventional
touch switches are
model, all control
automatically
touch switches are
created by register-
deleted.
ing alarm list/history
to the symbol man-
ager.
Touch switch size differs between NT20, NT20S, NT600S, NT620S and other PT
models.
Therefore, when the data of NT20, NT20S, NT600S, NT620S is converted to the
data for other PT models, touch switch position and size may change.
Control touch switches are annexed to alarm lists/his-
tories; correction is possible only with regard to the
position of the touch switches.
When converted to the NT21, NT31/631-V2 or later
models
(NT20/30/620-compatible
associated touch switches will keep other properties,
as it is, only thing is that it cannot be edited separately.
Control touch switches can be handled as indepen-
dent touch switches (to be associated with alarm lists/
histories). Their position, size, label, etc. can be
edited as desired.
When converted to the NT21, NT31/631-V2 models
(20/30/620 mode on) associated touch switches will
keep other properties, as it is, only thing is that it can-
not be edited separately.
Status after
Error Message
Conversion
[E]
Touch Switch func-
tion type is not sup-
ported. It is dis-
carded.
[W]
The associated
touch switches of
the alarm has been
discarded and com-
ponent touch
switches have been
created.
No error message
will be generated.
[W]
The associated
touch switches of
the alarm has been
discarded and com-
ponent touch
switches have been
created.
[W]
The component
Touch Switches of
the Alarm List will
be discarded.
Appendix A
mode
ON)
Corrective Action
Adjust the position of
control touch switches if
necessary. (Refer to 6-3
Alarm.)
If control touch switches
are not necessary, de-
lete them by setting in
the alarm list/history
properties. (Refer to 6-3
Alarm.)
Create the control touch
switches using the touch
switch control code input
function and associate
them with the alarm list/
history. (Refer to 6-8-5
Control Code Input
Touch Switches.)