Creating the Sample Data
Creating the numeral display field ([Numeral Display 2])
(6) Click the mouse with the mouse cursor set at the position where the nu-
meral display field is to be displayed (at the intended upper left corner of
numeral display).
(7) Set the properties as shown below.
General
Position
Font Type
Scale
Smoothing
Attribute
Color
Settings
Reference
Display Type
Format
Zero Suppression
Display Sign
(8) Adjust the position of the numeral display field by dragging it.
S Surrounding the numeral display field with a frame
(9) Select [Objects] (menu bar)
(10) On the data creation screen, drag the rectangle so that it encloses the nu-
meral display field.
(11) Use the properties as they are.
(12) Adjust the size and the position of the frame (rectangle).
S Copying and pasting the numeral display field ([Numeral Display 1])
(1) Copy the "Numeral Display 1" character string, numeral display field, and
its frame (rectangle).
(2) Paste the copied contents and move them to the desired position (for dis-
playing [Numeral Display 2]).
S Modifying to [Numeral Display 2]
(3) Double click the "Numeral Display 1" character string and modify the prop-
erties as shown below. Note that other properties must be left unchanged.
Section
Standard
2 2
n
Standard
Foreground
White
Background
Black
Indirect
Reference
Table Entry
0
Decimal
Integer
4
Decimal
0
n
n
[Fixed Display]
[Rectangle].