Data Conversion
Correction of smoothing processing for marks
Correction related to the system keypad
Correction of alarm list/history touch switches
474
S Conversion result, error message and corrective action
Status before
Status after
Conversion
Conversion
With a conventional
With a new model,
model, the inverse
the foreground color
attribute is specified
and background col-
for a graphic for
or are automatically
which the inverse at-
interchanged.
tribute is not sup-
ported by a new
model.
If a mark is converted between a conventional and a new model, conversion is
executed in the manner shown below due to differences in the handling of mark
smoothing processing between them.
S Difference
New models:
Conventional models:
S Conversion result, error message and corrective action
Status before
Status after
Conversion
Conversion
With a conventional
With a new model,
model, smoothing
smoothing proces-
processing is speci-
sing is invalid for a
fied for a mark.
mark.
If a system keypad is converted between a conventional and a new model, con-
version is executed in the manner shown below due to differences in the handling
of the system keypad between them.
S Difference
New models:
Conventional models:
S Conversion result, error message and corrective action
Status before
Conversion
With a conventional
With a new model,
model, a system
the system keypad
keypad is automati-
is invalid and thus
cally created with a
not displayed.
numeral setting in-
put screen.
If a touch switch for alarm list/history is converted between a conventional and a
new model, conversion is executed in the manner shown below due to differ-
ences in the handling of this kind of touch switch between them.
Error Message
[Object Name] –
inverse attribute not
supported. Fore-
ground and back-
ground colors inter-
changed.
Smoothing processing is not possible for marks.
Smoothing processing is possible for marks.
Error Message
[Fixed Display Mark]
smoothing not sup-
ported. It is ignored.
The system keypad cannot be set.
Numeric keys can be created automatically by setting
a system keypad.
Status after
Error Message
Conversion
––
Appendix A
Corrective Action
Since the foreground col-
or and background color
are automatically inter-
changed, no special
correction is required
(display attribute is set to
default (standard)).
Corrective Action
Correction not neces-
sary.
Corrective Action
Either copy the regis-
tered keyboard from the
symbol manager (refer
to 6-10 Registering
Created Elements (Sym-
bol Manager Opera-
tion)), or create numeric
keys that are equivalent
to a system keypad us-
ing the touch switch
control code input func-
tion (refer to 6-8-5 Con-
trol Code Input Touch
Switches).