Omron NT - SUPPORT TOOL FOR WINDOWS V4 Operation Manual page 170

Table of Contents

Advertisement

Fixed Display
(1) Click on at
the right side of the code after checking the [Direct] button in
the property setting dialog box to display the library data selection dialog
box.
(2) If the code of the desired library data is not found in the list, scroll the list us-
ing the scroll bar at the right side of the screen, or click on
open the code input dialog box.
Input the code of the desired library data and click on
By pressing cursor keys (°, ±) on keyboard, the contents of the code can be
checked in the preview window one by one.
(3) Select the code of the library data to be displayed.
The selected line will be highlighted.
(4) Click on
Indirect
Specify the numeral table entry to be referenced.
With indirect reference, the contents for the specified numeral table entry are
treated as a library code and the corresponding library data is displayed. This is
useful when you want to change the library data to be displayed according to the
statuses. Set the storage type of numeral table entry to be referenced by indirect
reference to Binary and specify the value (library code) to be stored in hexadeci-
mal since the library code is in hexadecimal.
Set the numeral table entry number to be referenced in the table entry number
field.
It is possible to display a numeral table entry so that you can select the desired
to close the dialog box.