Preparing Flat Connectors
1,2,3...
60
To prevent short-circuits, cut the cable with a sharp blade, such as wire cut-
ters, and be sure that there are no whiskers on the wires.
■ Setting the Cable Stopper (when Extending Cable or Connecting a
Terminating Resistor)
A stopper must be set in advance when extending a line or connecting a Ter-
minating Resistor.
Set the cable into the cover and position it so that the cable end strikes the
cable stopper.
■ Attaching the Cable
1. As shown in the diagram below, place the cable so that the white line is in
the direction of the side with the open cover, with the white line on the cable
facing upward.
(Top View)
Cable
White line
T-branch Connections
Cable stopper
Connector
Middle of connector
(Side with cover open)
White line