Units With Connectors; Eight-Point Input Units (E-Con Connectors) - Omron CRT1 - 10-2008 Operation Manual

Componet slave units and repeater unit
Table of Contents

Advertisement

Units with Connectors

5-4

Units with Connectors

5-4-1

Eight-point Input Units (e-CON Connectors)

CRT1-VID08S/CRT1-VID08S-1
Input Section Specifications
Model
I/O capacity
Internal I/O common
ON voltage
OFF voltage
OFF current
Input current
ON delay
OFF delay
Number of circuits per common
Isolation method
Input indicator
Installation
Power supply type
Power short-circuit protection
Current supplied to input devices 50 mA/input
Communications power supply
current consumption
Weight
Component Names and Functions (Same for CRT1-VID08S and CRT1-VID08S-1)
180
Item
8 inputs
NPN
10.5 VDC min. (between each
input terminal and the V terminal)
5 VDC max. (between each input
terminal and the V terminal)
1.0 mA max.
At 24 VDC: 6.0 mA max./input
At 11 VDC: 3.0 mA min./input
1.5 ms max.
1.5 ms max.
8 inputs/common
Photocoupler
LED (yellow)
DIN Track or Mounting Bracket
Network power supply
Operates at 50 mA/point min.
35 mA max. for 24-VDC power supply voltage
50 mA max. for 14-VDC power supply voltage
80 g max.
Top
(Mounted side)
Node address switches:
×10 and ×1 from mounted side
Specification
CRT1-VID08S
Front
Input indicators 0 to 7
Communications indicators:
MS and NS
Section 5-4
CRT1-VID08S-1
PNP
10.5 VDC min. (between each
input terminal and the G terminal)
5 VDC max. (between each input
terminal and the G terminal)
Bottom
Communications
connector
e-CON connectors

Advertisement

Table of Contents
loading

This manual is also suitable for:

Crt1 series

Table of Contents