Sign In
Upload
Manuals
Brands
OMRON Manuals
Repeater
CRT1 - 10-2009
OMRON CRT1 - 10-2009 Manuals
Manuals and User Guides for OMRON CRT1 - 10-2009. We have
1
OMRON CRT1 - 10-2009 manual available for free PDF download: Operation Manual
OMRON CRT1 - 10-2009 Operation Manual (675 pages)
CompoNet Slave Units and Repeater Unit
Brand:
OMRON
| Category:
Repeater
| Size: 14.11 MB
Table of Contents
Table of Contents
7
About this Manual
11
Related Manuals
12
Precautions
17
Intended Audience
18
General Precautions
18
Safety Precautions
18
Operating Environment Precautions
19
Application Precautions
20
Conformance to EC Directives
23
Section 1
25
Features and Slave Units
25
Features of Componet Slave Units
26
Overview
26
Componet Slave Unit Functions
31
Slave Unit Models
43
Word Slave Units
44
Units with Connectors
46
Units with Clamp Terminal Blocks
47
Expansion Units
49
Temperature Input Units
49
Bit Slave Units
50
Installing Slave Units
51
Repeater Units
51
Slave Unit Installation and Connection
51
Section 2 Wiring Configurations
55
Wiring Configurations
55
Componet Networks
56
Overall System Configuration and Elements
56
Segments
58
Wiring Formations
59
Communications Cable
61
Cables that Can be Used
61
Criteria for Selecting Cables
62
Maximum Distance and Number of Connected Units for Types of
64
Maximum Distance and Number of Connected Units for Types of Communications Cables
64
Communications Cable Wiring Examples
66
Round Cable I
66
Round Cable II
67
Flat Cable I/II
69
Section 3 Installation and Wiring
71
Installation and Wiring
71
Installing Slave Units
72
Installation Method
72
Installation Orientation
73
Mounting to a DIN Track
73
Mounting with a Mounting Bracket
74
Mounting with Screws
78
Screw Mounting with a Mounting Bracket
79
Connecting Cables
81
Round Cable I/II
81
Preparing Flat Connectors
82
Flat Cable I/II
82
Round Cable II
84
Flat Cable I
86
Flat Cable II
92
Connecting Cables and Terminating Resistor
97
Connecting Communications Cable to Slave Units and Repeater Units
98
Branching Communications Cables
101
Extending Communications Cables
104
Connection Locations for Terminating Resistor
106
Power Supply Wiring
109
Power Supply Specifications
110
Connection Locations for Communications Power Supplies
111
Connecting the I/O Power Supply
113
Connecting the Communications and I/O Power Supplies
115
Precautions When Supplying Communications Power
120
Precautions When Providing the I/O Power Supply
122
Other Precautions
123
Connecting External I/O for Slave Units
124
Connecting to a Screw Terminal Block
125
Connecting to E-CON Connector Terminals
126
Connecting to MIL Connector Terminals
129
Connecting to Screw-Less Clamp Terminal Blocks
135
Connecting External I/O to IP54 Bit Slave Units
136
Connecting to Compact Connectors
137
Section 4
139
Basic Specifications of Slave Units
139
Basic Specifications of Slave Units
140
Communications Specifications
140
Communications Indicators
141
Performance Specifications
141
Section 5 Digital I\/O Slave Units
143
Digital I/O Slave Units
143
Status Areas
144
Allocating I/O Data
145
Data Allocation for Word Slave Units
145
Data Allocation for Word Slave Units with Expansion Units
147
Units with Screw Terminal Blocks
149
Eight-Point Input Units (2-Tier Terminal Block)
149
Eight-Point Output Units (2-Tier Terminal Block)
153
Sixteen-Point Input Units (2-Tier Terminal Block)
158
Sixteen-Point Output Units (2-Tier Terminal Block with Transistor Outputs)
162
Eight-Point Input and Eight-Point Output Units (2-Tier Terminal Block)
166
Eight-Point Output Units (2-Tier Terminal Block with Relay Outputs)
171
Eight-Point Output Units (2-Tier Terminal Block with SSR Outputs)
176
Sixteen-Point Output Units (2-Tier Terminal Block with Relay Outputs)
180
Sixteen-Point Output Units (2-Tier Terminal Block with SSR Outputs)
185
Eight-Point Input Units (3-Tier Terminal Block)
189
Eight-Point Output Units (3-Tier Terminal Block)
196
Sixteen-Point Input Units (3-Tier Terminal Block)
201
Sixteen-Point Output Units (3-Tier Terminal Block)
207
Eight-Point Input and Eight-Point Output Units (3-Tier Terminal Block)
214
Units with Connectors
221
Eight-Point Input Units (E-CON Connectors)
221
Eight-Point Output Units (E-CON Connectors)
227
Sixteen-Point Input Units (E-CON Connectors)
233
Sixteen-Point Output Units (E-CON Connectors)
238
Eight-Point Input and Eight-Point Output Units (E-CON Connectors)
244
Thirty-Two-Point Input Units (E-CON Connectors)
252
Thirty-Two-Point Output Units (E-CON Connectors)
257
Sixteen-Point Input and Sixteen-Point Output Units (E-CON Connectors)
263
Sixteen-Point Input Units (MIL Connectors)
270
Sixteen-Point Output Units (MIL Connectors)
276
Thirty-Two-Point Input Units (MIL Connectors)
282
Thirty-Two-Point Output Units (MIL Connectors)
290
Sixteen-Point Input and Sixteen-Point Output Units (MIL Connectors)
297
Units with Clamp Terminal Blocks
306
Eight-Point Input Units (with Screw-Less Clamps)
306
Eight-Point Output Units (with Screw-Less Clamps)
310
Sixteen-Point Input Units (with Screw-Less Clamps)
314
Sixteen-Point Output Units (with Screw-Less Clamps)
319
Eight-Point Input and Eight-Point Output Units (with Screw-Less Clamps)
323
Section 6 Analog I\/O Slave Units
329
Analog I/O Slave Units
329
Analog I/O Slave Units
330
List of Data Processing Functions
330
Analog Output Slave Units
331
Summary of the Analog Input Slave Units
332
Input Range and Conversion Data
332
Calculation and Selection Processing of Input Data
335
I/O Data Type and Allocation
337
Summary of the Analog Output Slave Units
343
Output Range and Conversion Data
343
Status Areas
346
I/O Data Type and Allocation
346
Analog Input Slave Unit Status Area
347
Analog Output Slave Unit Status Area
348
Analog Data Monitor
349
Units with Screw Terminal Blocks
354
Four-Point Analog Input Slave Unit (with 2-Tier Terminal Block)
354
Two-Point Analog Input Slave Unit (with 2-Tier Terminal Block)
357
Units with Connectors
361
Four-Point Analog Input Slave Unit (with E-CON Connectors)
361
Two-Point Analog Output Slave Unit (with E-CON Connectors)
369
Four-Point Analog Input Slave Unit (with MIL Connectors)
374
Two-Point Analog Output Slave Unit (with MIL Connectors)
380
Section 7 Temperature Input Units
387
Temperature Input Units
387
Temperature Input Units
388
List of Data Processing Functions
388
Temperature Input Unit Display Modes
389
Overview of Temperature Input Units
391
Math Operations and Processing Input Data
391
I/O Data Type and Allocation
393
Status Areas
400
Monitoring Temperature Data
402
Temperature Input Units
406
Section 8 Expansion Units
415
Expansion Units
415
Expansion Units
416
Expansion Unit Specifications
418
Eight-Point Input Units
418
Eight-Point Output Units
421
Sixteen-Point Input Units
424
Sixteen-Point Output Units
427
Section 9 Bit Slave Units
431
Bit Slave Units
431
Status Areas
432
Allocating I/O Data
433
Bit Slave Units with E-CON Connectors
435
Two-Point Input Units
435
Two-Point Output Units
439
Two-Point Input Units (IP54)
443
Two-Point Output Units (IP54)
447
Four-Point Input Units (IP54)
451
Clamp Terminal Blocks
456
Two-Point Input/Two-Point Output Units (IP54)
456
Bit Slave Units with Compact Connectors
461
Bit Slaves with Compact Connectors
461
Two-Point Input Unit
462
Two-Point Output Units
466
Four-Point Input Unit
470
Four-Point Output Units
476
One-Point Input/One-Point Output Unit
481
Two-Point Input/Two-Point Output Unit
487
Repeater Units
495
Status Areas
496
Repeater Unit
498
Section 11 Smart Functions
503
Smart Functions
503
CX-Integrator
505
Offline Window
505
Online Window
506
Functions Common to All Slave Units
510
Automatic Baud Rate Detection
510
Hold/Clear Outputs
510
Network Power Voltage Monitor
511
Unit Conduction Time Monitor
512
Naming Units
514
Naming Connected Devices
515
Communications Error History Monitor
516
Last Maintenance Date
518
Functions of Digital I/O Slave Units
519
I/O Power Status Monitor (Digital I/O Slave Units Only)
519
Input Filter (Input Units Only)
520
Error Prevention for Surge Current at Startup (Input Units Only)
521
Contact Operation Monitor
522
Total on Time Monitor
523
Operation Time Monitor
526
Power Supply Short-Circuit Detection (Inputs)
528
Load Short-Circuit Detection (Outputs)
529
Analog I/O Slave Unit (Input) Functions
531
AD Conversion Point Setting (Only Input Unit)
531
Moving Average Processing
532
Scaling
533
Peak/Bottom Hold
537
Top/Valley Hold
539
Rate of Change Calculation
542
Comparator
544
Disconnected Line Detection
548
User Adjustment
548
Cumulated Count
550
Last Maintenance Date
553
Analog I/O Slave Unit (Output) Functions
554
Scaling
554
User Adjustment
558
Cumulated Count
561
Setting Output Value for Errors
563
Temperature Input Unit Functions
564
Moving Average Processing
564
Scaling
565
Peak/Bottom Hold
568
Top/Valley Hold
570
Top/Valley Counter
573
Rate of Change Calculation
574
Comparator
576
Temperature Range Count
580
Data Comparison between Channels
582
Input Error Detection Disable Function
584
Off-Wire Detection
585
Last Maintenance Date
585
Cumulated Counter
586
User Adjustment
589
Section 12 Troubleshooting and Maintenance
603
Troubleshooting and Maintenance
603
Indicator Meanings and Troubleshooting
604
Troubleshooting
605
Troubleshooting for Errors Shown by Indicators
605
Troubleshooting by Slave Unit Type
606
Device Maintenance
612
Cleaning
612
Inspections
612
Handling When Replacing Units
613
Componet Explicit Messages
615
Object Mounting
639
Analog Input Slave Units
646
Appendix B
650
Consumed con
650
Produced con
650
Consumed con
651
Produced con
651
Produced con
652
Consumed con
653
Current Consumption Summary
655
Precautions with Connecting Two-Wire DC Sensors
661
I/O Power Supply Current
663
Node Address Settings for Bit Slave Units with Compact Connectors
665
Produced con
653
Index
669
Revision History
673
Advertisement
Advertisement
Related Products
OMRON CRT1 - 10-2008
Omron CRT1 Series
Omron CR_UDG4_NR
Omron CR_UDG4_R
Omron CR UGD5 Series
Omron CR UGD5 XL Series
Omron CR UGD5 XS Series
Omron CR UGD4 XL Series
Omron CR UGD4 Series
Omron CR-UGD4MINI Series
OMRON Categories
Blood Pressure Monitor
Controller
Accessories
Switch
Inverter
More OMRON Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL