Analog Input Slave Units
I/O Data
Analog Data
Top/Valley Detection
Timing Flags (Shot Status)
306
4. Return to the General Tab Page, click the Transfer [PC to Unit] Button to
download the data, and then click the Reset Button to reset the Unit.
5. Click the OK Button and exit the window.
Analog Data is used to monitor analog values. Analog input value is allocated
as the default setting, but any one of analog input value, peak value, bottom
value, top value, valley value or rate of change can be selected as allocation
data.
Note The comparator function can be used for the data allocated in Analog Data.
The data format used for allocating data in the Master Unit is shown below.
Data is allocated as two's complements (8 bytes = 4 words).
15
These flags turn ON for the one-shot time when detecting the top or valley for
the top/valley hold function.
These flags are used to time reading the values held as the top and valley val-
ues at the Master Unit. The following data format is used when these flags are
allocated in the Master Unit (2 bytes = 1 word).
Bit 7
+0
0
+1
0
Analog Data 1 for Input 0
Analog Data 1 for Input 1
Analog Data 1 for Input 2
Analog Data 1 for Input 3
Bit 6
Bit 5
Bit 4
0
0
0
0
0
0
Section 6-4
0
Bit 3
Bit 2
Bit 1
V_ST3
V_ST2
V_ST1
T_ST3
T_ST2
T_ST1
Bit 0
V_ST0
T_ST0