Follow instructions in this section to remove and install a PCIe riser and a PCIe adapter installed on it.
Remove a PCIe riser
Follow instructions in this section to remove a PCIe riser.
About this task
Attention:
• Read
"Installation Guidelines" on page 45
work safely.
• Power off the server and peripheral devices and disconnect the power cords and all external cables. See
"Power off the server" on page
• If the server is installed in a rack, slide the server out on its rack slide rails to gain access to the top cover,
or remove the server from the rack. See
Note: To maintain proper system cooling, do not operate the server without a PCIe riser or a riser filler
installed in the chassis.
Watch the procedure
A video of this procedure is available at YouTube:
AgTVLhsU24Nhel3_oYlnGT
Select the PCIe riser removal scenario
There are three PCIe riser removal scenarios differentiated by PCIe riser location and serial port installation.
See corresponding instructions below for proper removal procedure.
ThinkSystem SR675 V3 User Guide
110
"Complete the parts replacement" on page
and
"Safety inspection checklist" on page 46
54.
"Remove the server from rack" on page
.
https://www.youtube.com/playlist?list=PLYV5R7hVcs-
194.
to ensure that you
54.