Lifting handles
1
Step 4.
Grasp the two lifting handles, and slide the system board assembly toward the rear of the chassis
until it clicks into place. Make sure that the rear connectors on the new system board assembly are
inserted into the corresponding holes in the rear panel.
Figure 116. System board assembly installation
Lifting handles
1
After you finish
1. Reinstall the following components.
a. Reinstall the power distribution board. See
b. Reinstall the power supply units. See
c. If applicable, reinstall the OCP module. See
d. Reinstall the intrusion switch. See
e. If applicable, reinstall the PCIe riser. See
f. Reinstall each memory module to the same slot on the new system board assembly as on the
defective system board assembly until all the memory modules are installed. See
module" on page
g. Reinstall the processors and the heat sinks. See
sink" on page
132.
h. Reinstall the air baffle. See
2. Reconnect all the required cables to the same connectors on the system board assembly as the
defective system board assembly.
3. Reinstall the fan cage and the fans. See
4. Ensure that all components have been reassembled correctly and that no tools or loose screws are left
inside the server.
5. Reinstall the top cover. See
6. If the sever was installed in a rack, reinstall the server into the rack. See
page
57.
7. Reconnect the power cords and any cables that you removed.
8. Power on the server and any peripheral devices. See
"Install a power supply unit" on page
"Install the intrusion switch" on page
"Install a PCIe riser" on page
102.
"Install the air baffle" on page
"Install the fan cage" on page 79
"Install the top cover" on page
"Install the power distribution board" on page
"Install the OCP module" on page
"Install a processor" on page 131
67.
155.
"Power on the server" on page
.
Chapter 5
Hardware replacement procedures
122.
124.
109.
91.
115.
"Install a memory
and
"Install a heat
and
"Install a fan" on page
"Install the server to rack" on
53.
77.
149