• If one or more EDSFF drives are to be removed, it is recommended to disable them beforehand via the
operating system.
• Before you remove or make changes to drives, drive controllers (including controllers that are integrated
on the system board assembly), drive backplanes or drive cables, back up all important data that is stored
on drives.
• Before you remove any component of a RAID array (drive, RAID card, etc.), back up all RAID configuration
information.
Note: Make sure you have the drive bay fillers available if some drive bays will be left empty after the
removal.
Watch the procedure
A video of this procedure is available at YouTube:
AgTVLhsU24Nhel3_oYlnGT
Procedure
Step 1.
Hold the handle of the EDSFF drive cage cover and pull it out of the server.
Figure 126. EDSFF drive cage cover removal
Step 2.
Remove the E1.S or E3.S hot-swap drive.
a.
Slide the release latch to unlock the drive handle.
b.
Rotate the drive handle to the open position.
c.
Grasp the handle and slide the drive out of the drive bay.