Paper Dehumidifying Heaters And Humidity Sensor - Minolta CF910 Service Manual

Hide thumbs Also See for CF910:
Table of Contents

Advertisement

1154SBM1306A

13-6. Paper Dehumidifying Heaters and Humidity Sensor

<Paper Dehumidifying Heaters>
• Paper Dehumidifying Heaters 1 to 4 H4 to H7 are provided to prevent damp paper from
adversely affecting the copy image.
• Each of these heaters is a 30W heater.
Deactuated
H4 to H7
OFF
From the time when the Start Key is pressed to the time
when PC Drum Drive Motor M18 is deenergized.
<Humidity Sensor>
• Humidity Sensor UN23 installed in the rear of the copier detects humidity and tempera-
ture inside the copier.
• Based on the humidity and temperature readings, the copier calculates the absolute
humidity for use in black toner replenishing control and image transfer, paper separator,
and charge neutralizing output control.
UN23
H4
Paper Dehumidifying Switch S2
Power cord
S1 ON
plugged in
ON
ON
Thermistor
Humidity Sensor
H6
M-77
Actuated
Misfeed/malfunction,
door open
ON
Temperature Data
Humidity Data
Calculating Absolute Humidity
Master Board PWB-I
S2
During copy
During
predrive
cycle
OFF
OFF
1144M036CB
1144M036CB
UN23
H5
H7
1144M062AA

Advertisement

Table of Contents
loading