Function Of Switches And Variable Resistors On Pwbs; Pwb Location; Tech. Rep. Setting Switches Board - Minolta CF910 Service Manual

Hide thumbs Also See for CF910:
Table of Contents

Advertisement

FUNCTION OF SWITCHES AND VARIABLE
3
RESISTORS ON PWBs
3-1.

PWB Location

3-2.

Tech. Rep. Setting Switches Board

Symbol
Name
S24
Trouble Reset
Switch
S25
TP1
GND Test
Point
TP2
Memory Clear
Test Point
INI
TROUBLE
S25
S24
DON'T USE
TP1
TP3
TOTAL MEMORY
Resets malfunctions in the fusing and exposure systems. In
addition, it forcibly resets a misfeed or malfunction that
occurrs due to incorrect operation, etc. and cannot be reset
by opening and closing the Front Door.
Disabled
Ground terminal used for memory clear.
See <List of Data Cleared by Switch and Point> on the next
page.