(20) Incorrect Image Registration

<Troubleshooting Procedure>
Symptom
Step
Defective IR
1
2
Defective PH
3
4
5
6
7
Check Item
Is the value for "Left Image" out of
correct adjustment?
Is the value for "Top Image" out of
correct adjustment?
Is the PH Lower Unit window dirty? YES
Is the value for "Left Margin" out of
correct adjustment?
Is the value for "Top Margin" out of
correct adjustment?
Is the SOS mirror dirty or
scratched?
Are the connectors on the SOS
Board connected properly?
T-87
1144T030AA
Result
YES
Readjust by referring to
DIS/REASSEMBLY,
ADJUSTMENT.
YES
Readjust by referring to
DIS/REASSEMBLY,
ADJUSTMENT.
Clean the window and
run "Gradation Adjust."
YES
Readjust by referring to
DIS/REASSEMBLY,
ADJUSTMENT.
YES
Readjust by referring to
DIS/REASSEMBLY,
ADJUSTMENT.
YES
Change the PH Upper
and Lower Assy.
NO
Reconnect the connec-
tors.
Action