(3) Cleaning and Replacement of the PC Drum Charge Corona Assy

Note:
Wipe the grid mesh in the
direction of the mesh.
1. Grid Mesh
Replace.
Note
2. Front Cover
Fig. 1 PC Drum Charge Corona wire installed position
Fit the wire into
the cutout.
(Front)
4. PC Drum Charge Corona Wire Assy.
Clean/replace.
Fig. 1
6. PC Drum Charge Wire Cleaning Motor
5. Cover
Fit the wire into the
shaded area.
D-66
9. PC Drum Charge Corona Housing
Clean.
(Rear)
1154D175AE
3. Rear Cover
1154D174AC
Hook the end
onto the cutout.

Advertisement