12. Remove the Screw Assy.
Note 3:
Do not touch the ATDC
Sensor window by hand.
Note 4:
When replacing the ATDC sensor Assy, check for
conductance between the Screw Assy terminal
and shaft. (See the illustration above.)
Fig. 9 Fixing Pipe Screw positions
BK
C
M
Y
Ensure that the screws are used at
the correct positions.
Screw Assy
ATDC Sensor Assy
Fig. 3
Screw positions
1,3
1,3
2,4
2,4
D-53
Note 4
Screw Assy Bushing (front)
Replace
1
4
1144D165AA
Fixing Pipe
Fig. 9
1154D160AB
2
3