(5) Adjustment of Manual Feed Paper Pick-Up Solenoid
Manual Feed Paper
Pick-Up Solenoid Assy
Fig. 1
Multi Bypass Table Assy
Fig. 1 Manual Feed Paper Pick-Up Solenoid Adjusting Procedure
3. Move the Solenoid in the direction of arrow 1 and then move it slowly in the direction
of arrow 2.
4. Move the Solenoid to a position at which the Paper Stopper Lock Levers are in the
upright position (at which the Paper Stoppers are locked). If the Solenoid is moved
too far, it will be released from the SET position. If it is released from the SET posi-
tion, energize the Solenoid and start the procedure over.
5. Tighten the two screws that secure the solenoid in position.
1. Manually move the Solenoid into the
energized position.
2. Loosen the adjusting screws.
1075D155AA
1075D156AB
D-109
1154D136AB
1075D157AB