Replacement Of The Ozone Filter (Pc Drum Charge Corona) And Cleaning Of The Main Erase Lamp - Minolta CF910 Service Manual

Hide thumbs Also See for CF910:
Table of Contents

Advertisement

(4) Replacement of the Ozone Filter (PC Drum Charge Corona) and Cleaning of the
Main Erase Lamp
3. Remove the PC Unit.
Note:
When removing the PC Front Frame Assy, first unlock the
Transfer Unit Lever and the Developing Unit Lock Lever.
Fig. 1
Cleaning of the PC Drum Heater
Terminal
PC Drum Heater Terminal
Clean.
1144D092AA
D-67
2. PC Front Frame Assy
Fig. 1 Note
5. Ozone Filter (PC Drum
1. PC Drum Charge
Corona Assy
6. Lamp Holder
Fig. 2
Ozone Filter position
When reinstalling the Ozone Filter, the Air
Filter goes underneath.
Charge Corona)
Replace. Fig. 2
7. Main Erase Lamp
Clean.
4. Cover
1154D280AB
Ozone
Filter
Air Filter
1144D259AA