1154SBM2203A
22-3. Power Supplies ON/OFF Control
DC5V
1
Power cord
plugged in
Power Switch
S1 ON
Door open
Malfunction
detected
Misfeed
detected
: Power ON ×: Power OFF
1: This is the power for the laser and is ON only during a copy cycle and predrive.
2: This is the power for options. It is not turned OFF when a malfunction occurs in the
copier, but is turned OFF if a communication failure occurs with the options.
1154SBM2204A
22-4. CPU Reset Function
• This copier is not equipped with a Tech. Rep. Setting Switches board as with the conven-
tional machines and the CPU is reset by the following way.
• The CPU is reset by turning OFF the DC5V2 output from DC Power Supply 1 PU1 for
a given period of time immediately after Power Switch S1 has been turned OFF.
Power cord
plugged in
DC5V2
PU1
ON
S1
OFF
1154SBM2205A
22-5. Power Supply Cooling Mechanism
• Power Supply Cooling Fan Motor M20: Draws air out of DC Power Supply 1 PU1 to
<Control>
M20
PWB-L PJ9L-7
ON
OFF
M20
DC5V
DC5V
DC±12V
2
3
×
Control Signal
Power Switch ON
M-133
DC Power Supply 1 PU1
DC±12V
DC24V
1
2
×
×
1
×
×
×
prevent the temperature of PU1 from rising.
ON
OFF
H
DC24V
DC24V
1
3
4
×
×
×
×
×
1154T46MCB
Wiring Diagram
L
31-D
Power OFF
1154T39MCA
DC24V
5
×
2