(4) Adjustment of Internal Fur Brush Solenoid, Backup Brush Solenoid, and Lifting
Finger Solenoid
Adjusting Screw
Lifting Finger
Solenoid
Fig. 2
Internal Fur Brush Solenoid
Fig. 1
Fig. 1 Internal Fur Brush Solenoid/Backup
Brush Solenoid Adjusting Procedure
1. Loosen the adjusting screw of the sole-
noid.
2. Adjust to obtain a clearance of 1 ±0.5
mm for the gap shown below when the
solenoid is manually moved into the
energized position.
Manually Move Solenoid
Into Energized Position.
Ensure that the spring is not stretched.
1 ±0.5mm
1144D201AA
D-108
Backup Brush Solenoid
Fig. 1
Fig. 2 Lifting Finger Solenoid Adjusting
Procedure
1. Loosen the adjusting screw of the sole-
noid.
2. Adjust to obtain a lift of 57 ±0.5 mm
from the joint face for the Lifting Finger
when the solenoid is manually moved
into the energized position.
Lifting Finger
Amount of
Lift
57 ±0.5mm
Mounting
Bracket
Adjusting Screw
1154D257AA
Arm
1154D258AA