Separator Misfeed>
Type
Leading-edge
separation
failure detection
Trailing-edge
separation
failure detection
<
Fusing,
Exit/Duplex Unit Take-Up Misfeed>
Type
Leading-edge exit
misfeed detection
Trailing-edge exit
misfeed detection
Duplex Unit
leading-edge
misfeed detection
Duplex Unit
trailing-edge
misfeed detection
<
Duplex Unit Transport Misfeed>
Type
Duplex Unit
storage failure
detection
Horizontal
Transport
leading-edge
misfeed detection
Separating Failure Detecting Sensor PC21 is not blocked ( L ) even
after the lapse of approx. 2.2 sec. after Paper Separator Finger Sole-
noid SL14 has been energized (At two-sheet attraction).
PC21 is not blocked ( L ) even after the lapse of approx. 4.8 sec. after
SL14 has been energized (At single-sheet attraction).
• PC21 is not deactivated even after the lapse of approx. 2.3 sec.
after it has been activated (at two-sheet attraction).
• PC21 is not deactivated even after the lapse of approx. 4.6 sec.
after it has been activated (at single-sheet attraction).
Paper Exit Switch S10 is not actuated even after the lapse of approx.
2.5 sec. after PC21 has been activated.
S10 is not deactuated even after the lapse of approx. 4.8 sec. after it
has been actuated.
Vertical Transport Sensor PC3 of the Duplex Unit is not blocked ( L )
even after the lapse of approx. 3.3 sec. after S10 has been actuated.
PC3 of the Duplex Unit is not unblocked ( L ) even after the lapse of
approx. 3.3 sec. after S10 has been deactuated.
Switchback Sensor PC1 of the Duplex Unit is not blocked ( L ) even
after the lapse of approx. 1.3 sec. after PC3 of the Duplex Unit has
been activated.
Horizontal Transport Sensor PC24 is not blocked ( L ) even after the
lapse of approx. 2.1 sec. after PC1 of the Duplex Unit has been acti-
vated.
Detection Timing
Detection Timing
Detection Timing
T-8