Minolta CF910 Service Manual page 489

Hide thumbs Also See for CF910:
Table of Contents

Advertisement

If the printer is not printing, restart the Facte.exe
program.
This screen appears before the print cycle is
completed.
1. Switch the Swticher to the "B" X-Rite position. (If
the switch position is not changed, the PC screen
shows "_".)
2. To read the test print, click the "Read TestPrint"
button.
3. To calibrate the X-Rite, click the "Start DTP32
Calibration" button.
NOTE:
Calibration is necessary when the message
"NEEDS CALIBRATION" appears, or at roughly a
weekly frequency.
5. Calibrate X-Rite.
Insert the X-Rite Auto Cal Strip into the strip insertion
slot.
Go to the next step when this LCD screen appears.
Test Print
6. Read the cyan data.
Wait until the message "Insert Cyan Pass" appears.
Set the X-Rite guide to 15 and slowly pass the test
print through the X-Rite from the front so it can read
the cyan data. This lets X-Rite start reading the data
automatically.
7. Read the magenta data.
Wait until the message "Insert Magenta Pass"
appears. Set the X-Rite guide to 30 and slowly pass
the test print through the X-Rite from the front so it
can read the magenta data.
8. Read the yellow data.
Wait until the message "Insert Yellow Pass" appears.
Set the X-Rite guide to 10 and slowly pass the test
print through the X-Rite from the front so it can read
the yellow data.
9. Read the black data.
Wait until the message "Insert Black Pass" appears.
Set the X-Rite guide to 25 and slowly pass the test
D-137-2