Focus-Positioning Of The Scanner And 2Nd/3Rd Mirrors Carriage - Minolta CF910 Service Manual

Hide thumbs Also See for CF910:
Table of Contents

Advertisement

(2) Focus-Positioning of the Scanner and 2nd/3rd Mirrors Carriage

Scanner/Mirrors Carriage
Positioning Jig ×2
2nd/3rd Mirrors Carriage
Fig. 1 Adjusting Procedure
1. Loosen the Scanner positioning screws.
2. Install the Scanner/Mirrors Carriage Positioning Jigs.
3. Press the Scanner and 2nd/3rd Mirrors Carriage up against the jigs as shown
above.
4. If there is a clearance between the jig and 2nd/3rd Mirrors Carriage, loosen the
cable fixing screw on the front frame and move the adjusting screw in the adjust-
able anchor to eliminate the clearance.
5. Tighten the Scanner positioning screws.
D-139
Scanner
Positioning
Screw ×2
Fig. 1
1144D219AC
1144D220AA