Task
Fuser Nip
Fuser Speed
Fuser Temp.
Transfer Output
Jam Sensor
Feed Motor Speed
PRT Area
Top Margin
Image Start Position
Lead Edge Position
Left Margin
Dup. Left Margin
IR Area
Left Image
Top Image
CD-Mag
FD-Mag
ADF Original Stop Position Set
Paper Loop
A6 Card Passage (Metric Areas)
4x6 Paper Passage (Inch Areas)
Paper Size
Paper Kind
Admin. Mode
RD Mode
Manual Paper width
Org. Detect Sensor
Serial # Input
CH Cleaning
OHP Speed
Transfer Table
Editor Screen
A6 Card Margin (Metric Areas)
4x6 Paper Margin (Inch Areas)
: Reentry of values before replacement
12. Reinstall the Rear Cover.
13. Turn OFF, then ON, the Power Switch to return to the initial screen.
14. Select "Gradation Adjust" available from the Service Mode and make the Gradation
Adjust three times.
Procedure
Automatic adjustment
Automatic adjustment
Check that "155°C" has been set. Set
to "155°C" if set otherwise.
Automatic adjustment
Automatic adjustment
Automatic adjustment
Automatic adjustment
Check that "1" has been set. Set to
"1" if set otherwise.
: Adjustment ∆: Check