Other Factory Modes

ENTER
INITIALIZE ALL
SYS.PARAMETER
[ ]
SELECT MODEL
LEF2-200
[ ]
INITIALIZATION
COMPLETED
Language/unit selection
+
MENU
Roland DG Corp.
     LEF-300
MENU LANGUAGE
ENGLISH
[ ]
LENGTH UNIT
mm > INCH
[ ]
TEMP. UNIT
°C
>
°F
1
System parameter initialization
+
Turn on the sub power switch while pressing the [] [] [ENTER]
keys to start the printer in system parameter initialization mode . The
confirmation message will be shown on LCD . Press the [ENTER] key to
switch to [Select Machine] menu . Select the model by pressing the
[] [] keys . Press the [ENTER] key to initialize system parameters .
Press and hold the sub power switch to cancel it . The sub power
switch is turned off automatically when the initialization is complete .
All the parameters are reset to the default . History menu will be
cleared .
The limit position will be cleared . It is necessary to initialize the limit
position after this initialization . [SERVICE CALL 0101] occurs if the limit
position is not initialized .