Encoder Scale Replacement
Cover That Needs to Be Removed
Workflow
C AUTION
• To prevent hardened ink from entering into the nozzle, refresh print head before the replacement . Perform medium
cleaning on all print heads if 20 minutes passes .
FUNCTION
CLEANING
MEDIUM CL.
• Always use the UV protection sheet during this adjustment, or ink will harden and clog inside the ink line .
1.
Remove the plate that secures the right side of the encoder scale . Also, remove the spring on the left side . Then, remove
the encoder scale .
2
FUNCTION
CLEANING
MEDIUM CL.
AB
3
3
1
Panel cover
1 . Plate
2 . Spring
3 . Encoder scale
1-99
1
L EF 2-200