Table Height Adjustment
• This adjustment is to adjust the table height parallel to the LM guide . This adjustment is required when the table unit
is replaced . This adjustment is NOT required when you remove the table unit and replace the same one . After this
adjustment, following adjustments are required:
- Head height adjustment
- UV lamp position adjustment
- Head gap sensor adjustment
- Print area adjustment
• A parallelepiped block is required for this adjustment .
• Recommended media for this adjustment is PET-G .
1.
Remove the head gap sensor .
2.
Tape the sensor plate shown in the figure in the place to deauthorize the head gap sensor .
3.
Turn on the main power switch, and then turn on the sub power switch while pressing [] [] [] keys to enter the
service mode .
MENU
SERVICE MENU
1
+
MENU
1 . Head gap sensor
2-67
2
L EF 2-200