Board Replacement
17.
Unplug the connectors and disconnect the ribbon cable from the main board and DC junction board, and remove the
second board stay .
SW power supply (41V) replacement
18.
Remove SW power supply (41V), and replace it with a new one .
C AUTION
In the case that the volume is accidentally turned, adjust the output voltage value to +41 +/- 0 .1 .
SW power supply (5V) replacement
19.
Remove SW power supply (5V), and replace it with a new one .
C AUTION
In the case that the volume is accidentally turned, adjust the output voltage value to +5+/- 0 .1 .