Head Gap Sensor Position Adjustment
13.
Loosen three screws that secure the head gap sensor plate .
14.
Tighten three screws while pushing the head gap sensor plate upward .
15.
Perform [SERVICE MENU] > [MOTOR MENU] > [AXIS MOVE] > [HEIGHT] and set the Height to 102 .1 mm and move the table
to the center of the machine by pressing the
1
Key .
[] []
2-94