Error Code
Code
Error Name
0211
UV lamp error
0212
Lamp slide error
0230
Feed motor error
0231
HEIGHT motor error
Contents
Cause
There is a bad connection
between the UV junction board
and the signal junction board.
The UV junction board is
broken.
The UV lamp is broken. /
The signal junction board is
There is a problem with the
broken.
UV Lamp.
The filter of the UV lamp is
The thermistor in the UV
clogged.
lamp is extremely high.
The UV lamp is broken.
*When the bad connections
happen at the same time,
Service Call [0211] occurs as a
high priority.
Defect of the lamp slide unit
The lamp slide unit does not
Defect of the limit board
work correctly.
Cut-line or short-circuit of cable
and flexible cable
Feed motor error
Defect of the feed motor gear
The feed origin sensor does
Defect of the feed belt
not work correctly.
Defect of the feed origin sensor
Cut-line or short-circuit of cable
and flexible cable
Table motor error
Defect of the table unit
The table height origin
Defect of the table height
sensor does not work
origin sensor
correctly.
Cut-line or short-circuit of
cable and flexible cable
Action
Check cable connection between the print carriage
board and the signal junction board.
Print carriage board replacement
Signal junction board replacement
UV lamp filter replacement
UV lamp replacement
Lamp slide unit replacement
Limit board replacement
Cable and flexible cable replacement
Feed motor replacement
Feed motor gear replacement
Feed belt replacement
Feed origin sensor replacement
Cable and flexible cable Replacement
Table unit replacement
Cable and flexible cable replacement
Grease up maintenance