Low Temperature Alarm Test Srmo And Srme - Nortel DMS-100 Series Maintenance Manual

Star remote system
Hide thumbs Also See for DMS-100 Series:
Table of Contents

Advertisement

Application
Use this procedure to test the low temperature alarm in the Star Remote
Module Outside (SRMO) cabinet and Star Remote Module Inside (SRME)
Wall Mount.
Interval
Perform this procedure every 12 months.
Common procedures
This procedure does not refer to any common procedures.
Action
The flowchart that follows provides a summary of this procedure. Use the
instructions in the step-action procedure that follows the flowchart to perform
the routine maintenance procedure.
Star Remote System routine maintenance procedures 13-31
Low temperature alarm test
DMS-100 Family NA100 Star Remote System XPM15 and up
SRMO and SRME