Nortel DMS-100 Series Maintenance Manual page 529

Star remote system
Hide thumbs Also See for DMS-100 Series:
Table of Contents

Advertisement

If
load passes
load fails
9
To return the STAR unit to service, type
>RTS UNIT unit_no
and press the Enter key.
where
unit_no
is the STAR busied in step 5 (0 or 1)
If RTS
passes
fails
10
Determine the type of device where the PM load files are located.
If load files are located on
IOC disk
SLM disk
11
Locate the tape that contains the PM load files.
At the IOE frame
12
Mount the tape on a magnetic tape drive.
At the MAP display
13
To download the tape, type
>MOUNT tape_no
and press the Enter key.
where
tape_no
is the number of the tape drive containing the PM load files
14
To list the contents of the tape in your user directory, type
>LIST T tape_no
and press the Enter key.
where
tape_no
is the number of the tape drive containing the PM load files
Star Remote System card replacement procedures
DMS-100 Family NA100 Star Remote System XPM15 and up
in a STAR
Do
step 9
step 29
Do
step 27
step 29
Do
step 17
step 22
12-181
NTTR77
(continued)