Nortel DMS-100 Series Maintenance Manual page 291

Star remote system
Hide thumbs Also See for DMS-100 Series:
Table of Contents

Advertisement

link_no
is the number of the link associated with the host LTC (see step 20
display)
Repeat the POST command for each link.
Example MAP response:
N CLASS
SITE LTC CK D ALRM SLIP FRME
0 REMOTE HOST
Note 1: The number that appears under the CK (circuit) header is the host
XPM link number.
Note 2: This display shows carrier facilities from the host XPM to the
STAR. Using the Detail REM option, the carrier facilities should also be
checked from the remote site back to the host XPM.
If link conditions show
a high number of SLIP and
FRME
a very low number of SLIP and
FRME
23
Post the STAR with the alarm condition by typing
>PM; POST STAR site frame unit
and pressing the Enter key.
where
site
is the site name of the STAR (alphanumeric)
frame
is the frame number of the STAR (0-511)
unit
is 0 for the STAR
24
Busy both units of the STAR by typing
>BSY PM
and pressing the Enter key.
25
Test both units of the STAR by typing
>TST PM
and pressing the Enter key.
If test
passed
Star Remote System alarm clearing procedures
1
0 C
DMS-100 Family NA100 Star Remote System XPM15 and up
critical
BER
ES SES STATE
0
0
1
0
Do
Leave the STAR in ESA. Go to
step 29.
step 23
Do
step 27
11-25
PM STAR
(continued)
0
INSV

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents