Nortel DMS-100 Series Maintenance Manual page 293

Star remote system
Hide thumbs Also See for DMS-100 Series:
Table of Contents

Advertisement

31
Go to the "Star Remote Hub card replacement procedures" in this manual.
Replace the first (or next) card on the card list. Notify outside plant personnel
the card is to be changed. Go to step 28 when the card is replaced.
32
Attempt to load the STAR unit by typing
>LOADPM UNIT star_unit
and pressing the Enter key.
where
star_unit
is the unit of the STAR to be loaded (0 or 1)
If load is
successful
not successful
33
Test the STAR unit by typing
>TST UNIT star_unit
and pressing the Enter key.
where
star_unit
is the unit of the STAR to be tested (0 or 1)
If test
passed
failed, and a card list is generat-
ed
failed, but no card list was gen-
erated
34
Attempt to return the STAR unit to service by typing
>RTS UNIT star_unit
and pressing the Enter key.
where
star_unit
is the unit of the STAR to be returned to service (0 or 1)
If RTS
passed
failed
Star Remote System alarm clearing procedures
DMS-100 Family NA100 Star Remote System XPM15 and up
critical
Do
step 33
step 30
Do
step 34
step 26
step 30
Do
step 35
step 30
11-27