Nortel DMS-100 Series Maintenance Manual page 311

Star remote system
Hide thumbs Also See for DMS-100 Series:
Table of Contents

Advertisement

If the fault indicated is
UMP load file mismatch
At the STAR site
6
Inspect the ringing generator to see if the Fail light-emitting diode (LED) is lit.
If the Fail LED is
lit
not lit
7
Power up the ringing generator by setting the circuit breaker on the FSP to
the ON position. (The Pack failure LED light should go OFF.) These circuit
breakers are identified as follows:
circuit breaker marked Ring0, Slot1 controls the ringing generator in unit
0, slot 1
circuit breaker marked Ring1, Slot22 controls the ringing generator in unit
1, slot 22
8
Determine if power is restored to the ringing generator.
If power
restores and neither unit is SysB step 61
restores and one unit is SysB
does not restore
9
To perform an in-service test on the STAR to clear the RG fault, type
>TST PM
and press the Enter key.
If the TST
passes
fails and a card list is produced
At the MAP terminal
10
To identify C-side links to the host PM, type
>TRNSL C
and press the Enter key.
Example of a MAP response:
Star Remote System alarm clearing procedures
DMS-100 Family NA100 Star Remote System XPM15 and up
minor
Do
step 53
Do
step 7
step 49
Do
step 49
step 49
Do
step 61
step 60
11-45
PM STAR
(continued)