Nortel DMS-100 Series Maintenance Manual page 391

Star remote system
Hide thumbs Also See for DMS-100 Series:
Table of Contents

Advertisement

Replacing an NT6X76 card in a STAR or RLD
At your current location
1
Proceed only if you have been directed to this card replacement procedure
from a step in a maintenance procedure, are using the procedure for verifying
or accepting cards, or have been directed to this procedure by your
maintenance support group.
2
Get a replacement card. Make sure the replacement card has the same
product equipment code (PEC), including suffix, as the card that is to be
removed.
At the MAP terminal
3
To post the LEN of the card to be replaced, type
>MAPCI;MTC;LNS;LTP; POST STAR site frame unit lsg ckt
and press the Enter key.
where
site
is the name of the site where the STAR is located
frame
is the frame number of the STAR with the faulty card (0 to 511)
unit
is 0 for the STAR
lsg
is the number of the line subgroup with the faulty card (0 to 35)
ckt
is the number of the circuit associated with the faulty card (0 to 31)
Example of a MAP response:
Post
LCC PTY RNG....LEN...
CKT TYPE FL
4
To busy the NT6X76 line card, type
>BSY
and press the Enter key.
Example of a MAP display:
Post
LCC PTY RNG....LEN......
CKT TYPE FL
Star Remote System card replacement procedures
in a STAR or RLD
DELQ
BUSYQ
HOST 00 0 03 03
DELQ
BUSYQ
HOST 00 0 03 03
DMS-100 Family NA100 Star Remote System XPM15 and up
PREFIX
DN
STA F S LTA TE RESULT
PREFIX
DN
STA F S LTA TE RESULT
12-43
NT6X76
(continued)

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents