11-68 Star Remote System alarm clearing procedures
PM STAR RG
major, minor
Alarm display
CM
.
Indication
A major alarm involving a STAR is indicated by nLRG under the PM
subsystem header with an M beneath it at the MTC level of the MAP display.
Meaning
One of the ringing generator units is in the system busy (SysB) state.
Impact
Service is not affected since a switching of support to a backup ringing
generator (SwRG) automatically occurs. However, if the backup ringing
generator fails, ringing will not be produced.
Common procedures
None
Action
The following flowchart is only a summary of the procedure. Use the
instructions in the step-action procedure that follows the flowchart to clear the
alarm.