Nortel DMS-100 Series Maintenance Manual page 346

Star remote system
Hide thumbs Also See for DMS-100 Series:
Table of Contents

Advertisement

11-80 Star Remote System alarm clearing procedures
STAR talk battery
critical
(continued)
Clearing a STAR talk battery critical alarm
At the MAP terminal
1
2
3
4
5
297-8353-550 Standard 05.01 March 2001
To silence the alarm, type
>MAPCI;MTC;SIL
and press the Enter key.
To access the PM level of the MAP display, type
>PM
and press the Enter key.
To identify the STAR with faults, type
>DISP STATE ISTB STAR
and press the Enter key.
To post the STAR which has lost talk battery, type
>POST STAR site frame unit
and press the Enter key.
site
is the site name of the STAR (alphanumeric)
frame
is the frame number of the STAR (0-511)
unit
is 0 for the STAR
Example of a MAP display:
SysB
ManB
PM
0
0
STAR
0
0
STAR REM1 00 0 ISTb Links_OOS: CSide 0 PSide 0 UMP OOS:0
Unit 0: ISTb
/RG: 0
Unit 1: ISTb
/RG: 0
Drwr:
11 11 11 11 11 22 22 22 22 22 33 33 33 Pref 0 InSv
01 23 45 67 89 01 23 45 67 89 01 23 45 67 89 01 23 45 Stby 1 InSv
.. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. ..
To check for fault indicators, type
>QUERYPM FLT
and press the Enter key.
Example of a MAP response:
OffL
CBsy
ISTb InSv
2
0
1
2
0
1
RG:
12
9

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents