7-14 Star Remote System manual maintenance
Star Module log reports
The Star Module reports on various conditions using ISDN and PM logs. The
following table lists the log reports and the conditions that cause the switch to
output these log reports.
Table 7-13 Star Module log reports (Sheet 1 of 4)
Log
report
Reason for output
PM179
Hardware exception
report
PM180
Hardware or software
exception report
297-8353-550 Standard 05.01 March 2001
Meaning
Carrier line failure, carrier link
recovery, DS-1 alarm
If a hardware exception, the
report can be one of the
following:
•
RLD drawer alarms
•
scan point alarm
•
P-side link alarms
•
RLD links alarms
•
RLD diagnostic failed
•
RLD failure
•
RLD link failure
•
RLD link recovery
Software failed to execute
properly.
Action
Perform diagnostic and
maintenance procedures
on suspect hardware.
No action required.
Retain the log for trend
analysis.