Nortel DMS-100 Series Maintenance Manual page 338

Star remote system
Hide thumbs Also See for DMS-100 Series:
Table of Contents

Advertisement

11-72 Star Remote System alarm clearing procedures
PM STAR RG
major, minor
(continued)
Clearing a PM STAR RG major, minor alarm
At the MAP terminal
1
2
3
297-8353-550 Standard 05.01 March 2001
You should be entering this procedure from the PM system level alarm
clearing procedure step which identified a PM alarm associated with a STAR
ringing generator fault.
To silence the alarm, type
>MAPCI;MTC;PM;SIL
and press the Enter key.
To identify the STAR with faults, type
>DISP STATE ISTB STAR
and press the Enter key.
Example of a MAP response:
ISTb:
REM1 14 1
To post the ISTb STAR identified in step 2, type
>POST STAR site frame unit
and press the Enter key.
where
site
is the name of the site where the STAR is located
frame
is the number of the frame (00 to 511)
unit
is 0 for the STAR
Example of a MAP response
ATTENTION