Nortel DMS-100 Series Maintenance Manual page 342

Star remote system
Hide thumbs Also See for DMS-100 Series:
Table of Contents

Advertisement

11-76 Star Remote System alarm clearing procedures
PM STAR RG
major, minor
(continued)
14
15
16
17
297-8353-550 Standard 05.01 March 2001
To align RG activity to the new RG, type
>SWRG UNIT unit_no
and press the Enter key.
where
unit_no
is the STAR unit (0 or 1) associated with the new RG
Example of a MAP display:
STAR REM1 14 1 Unit 1 SWRG Passed
If the SWRG command
passes, and RG activity must be switched for the
other STAR unit
passes, and RG activity is acceptable for both STAR
units
fails
Repeat step 14 for the other STAR unit in this frame.
To test the new RG, type
>TST UNIT unit_no
and press the Enter key.
where
unit_no
is the number of the STAR unit (0 or 1)
Example of a MAP response:
STAR REM1 14 1 Unit 1 InSvce Tests Initiated
STAR REM1 14 1 Unit 1 Tst
Note: Repeat this step for the other STAR unit.
If TST
passes
fails
To align RG activity to the preferred RG, type
>SWRG UNIT unit_no
and press the Enter key.
Passed
Do
step 17
step 19
Do
step 15
step 20
step 19

Hide quick links: